H20-923_V1.0 Pre-Exam Practice Tests (Updated 62 Questions) [Q37-Q58]

이 게시물 평가하기

H20-923_V1.0 Pre-Exam Practice Tests | (Updated 62 Questions)

Valid H20-923_V1.0 Exam Q&A PDF – One Year Free Update

Huawei H20-923_V1.0 Exam Syllabus Topics:

주제 세부 정보
주제 1
  • Introduction to the Modular Data Center FusionModule2000: This topic introduces the FusionModule2000 modular data center, covering its design concepts, components, and the scenarios in which it is deployed.
주제 2
  • iManager NetEco 6000 Product Introduction: This topic covers the iManager NetEco 6000 platform, explaining its capabilities as a network and infrastructure management tool used within Huawei data center environments.
주제 3
  • SmartLi 3.0 (Short-Term Backup Power) Maintenance Operations: This topic addresses the routine and corrective maintenance tasks for SmartLi 3.0, including battery management, fault handling, and health monitoring procedures.
주제 4
  • Huawei Data Center Facility Solutions: This topic provides an overview of Huawei’s end-to-end data center facility portfolio, covering the key product lines and solution architectures used in modern data center environments.
주제 5
  • SmartLi 3.0 (Short-Term Backup Power) Product Introduction: This topic introduces Huawei’s SmartLi 3.0 lithium-based short-term backup power solution, covering its product architecture, key features, and application scenarios.
주제 6
  • Huawei FusionCol8000-A Lab Guide: This is a heavily weighted practical lab section focused on the hands-on deployment, configuration, commissioning, and maintenance of the FusionCol8000-A cooling system in a field-representative setting.
주제 7
  • FusionCol8000-A230 In-Room Air Cooled (Air-Cooled Fan Wall) Smart Cooling Product: This topic addresses the FusionCol8000-A230 air-cooled fan wall solution, covering its working principles, product specifications, installation considerations, and smart cooling management capabilities.
주제 8
  • Huawei DCIM Lab Guide: This topic is a broader practical lab section covering operational tasks, configuration, and troubleshooting exercises across Huawei DCIM platforms to build field-level proficiency.
주제 9
  • Huawei UPS5000H Lab Guide: This is a heavily weighted hands-on lab section covering practical installation, commissioning, parameter configuration, and maintenance operations for the UPS5000H in a field-simulated environment.
주제 10
  • UPS Basic Knowledge: This topic introduces the foundational concepts of Uninterruptible Power Supply systems, including operating modes, topology types, and their role in ensuring power continuity for data center loads.
주제 11
  • Introduction to Huawei Precision Air Conditioners: This topic introduces Huawei’s precision air conditioning product line, covering unit types, operating principles, key components, and their role in maintaining optimal data center temperatures.
주제 12
  • Basic Knowledge of Power Distribution: This topic covers the fundamental concepts of power distribution within a data center, including electrical principles, distribution topologies, and key components such as switchgear and PDUs.
주제 13
  • Data Center Cooling Solutions: This topic provides an overview of cooling technologies and strategies used in data centers, including air-side and water-side cooling architectures and Huawei’s approach to thermal management.
주제 14
  • FusionCol8000-C (110-440) In-Room Chilled Water Smart Cooling Product: This topic covers the FusionCol8000-C chilled water in-room cooling unit, including its product design, chilled water system integration, smart control features, and deployment scenarios.
주제 15
  • Training on FusionDC1000A: This topic focuses on the FusionDC1000A prefabricated data center solution, covering its product features, deployment methods, and operational maintenance requirements.
주제 16
  • UPS5000H Product Training: This topic provides in-depth product training on the Huawei UPS5000H, covering its technical specifications, system architecture, operating modes, and configuration options.
주제 17
  • SmartLi 3.0 (Short-Term Backup Power) Installation: This topic covers the installation procedures for the SmartLi 3.0 system, including hardware setup, cabling requirements, and commissioning steps.
주제 18
  • Introduction to Huawei DCIM Controller ECC800-Pro: This topic introduces the ECC800-Pro Data Center Infrastructure Management controller, covering its architecture, core functions, and role in monitoring and managing data center facility equipment.
주제 19
  • Huawei Other DCIM Tools: This topic explores additional Huawei Data Center Infrastructure Management tools beyond the ECC800-Pro and NetEco 6000, covering their functions and how they complement the overall DCIM ecosystem.
주제 20
  • Huawei DCIM Installation and Deployment Lab Guide: This topic is a guided hands-on section covering the step-by-step installation and initial deployment procedures for Huawei DCIM systems in a lab environment.

 

Q37. The default port number for logging in to the NetEco is

 
 
 
 

Q38. Which of the following is the procedure for replacing a damaged UPS power module onsite?

 
 
 
 

Q39. Which O&M practice is most effective for identifying cooling inefficiency caused by airflow problems in an operating data center?

 
 
 
 

Q40. Which of the following is the cabling mode of external power cables in IT scenarios of the FusionDC1000A?

 
 
 
 

Q41. Huawei-developed intelligent rPDU (PDU2000M) can replace the original UIM20A expansion module. The rPDU can connect to the cabinet temperature/humidity sensors, smart U space managers, and door status sensors.

 
 

Q42. The UPS5000-H-1200 kVA and UPS5000-H-1600 kVA have two power cabinets and one bypass cabinet, and are equipped with the MDU, ECU, and surge protection box.

 
 

Q43. The maintenance bypass switch cannot be turned on when the UPS5000-H works in normal mode.

 
 

Q44. After the battery module is installed, the torque and insulation should be checked according to the specified requirements.

 
 

Q45. Which of the following control modes can be used for temperature and humidity control of smart cooling products?

 
 
 
 

Q46. After replacing the fan, choose “Menu > _____ > Performance Maintenance” on the main screen to enter the
“Performance Maintenance” screen and clear the accumulated runtime of the indoor fan.

 
 
 
 

Q47. Which of the following statements are true about the routine maintenance of a UPS?

 
 
 
 

Q48. When tightening the screws (M16x50 mm) for the output power cables of lithium battery cabinets, what torque should be used to tighten and verify the screws?

 
 
 
 

Q49. In IT scenarios, which of the following are the power supply and distribution components of the FusionDC1000A?

 
 
 
 

Q50. After installing the FusionCol8000-C (110-440 kW), inject water to preserve the pressure for the chilled water pipes to how many MPa. After 30 minutes, check that no leakage occurs. Preserve the pressure for 24 hours. If the pressure drop is less than 0.01 MPa and no leakage occurs, the pipes do not leak.

 
 
 
 

Q51. ECO mode is not recommended when the load is less than

 
 
 
 

Q52. Video management can connect to the third-party video surveillance subsystem and play historical videos.

 
 

Q53. If a component runtime overdue alarm is generated for an air conditioner, you can clear the device running time on the “Maint > Performance Maintenance” screen.

 
 

Q54. After the unit is powered on for the first time, it enters the compressor preheating state. To quickly perform power-on commissioning, you can manually shut down the compressor preheating.

 
 

Q55. Which of the following is not a scenario-based solution for Huawei data center products?

 
 
 
 

Q56. When the outdoor unit is installed at a position higher than the indoor unit, install an oil trap every five to six meters in the vertical direction along the gas pipe to ensure system reliability.

 
 

Q57. Which of the following statements is false about how to start an electric heater?

 
 
 
 

Q58. During wizard startup, when you enter the screen for selecting commissioning items for the first time, all items are selected by default. Which item is mandatory. You can deselect other commissioning items that are not mandatory.

 
 
 
 

HCSP-Field-Data Center Facility V1.0 Free Update Certification Sample Questions: https://www.passtestking.com/Huawei/H20-923_V1.0-practice-exam-dumps.html